mirror of
https://github.com/munin-monitoring/contrib.git
synced 2018-11-08 00:59:34 +01:00
Plugin to check fanspeed readings from a Thecus NAS server.
This commit is contained in:
parent
3c6692940b
commit
031d4e669f
104
plugins/sensors/snmp__thecus_fans
Executable file
104
plugins/sensors/snmp__thecus_fans
Executable file
@ -0,0 +1,104 @@
|
||||
#!/usr/bin/perl -w
|
||||
# -*- cperl -*-
|
||||
|
||||
=head1 NAME
|
||||
|
||||
snmp__thecus_fans - Munin plugin to retrive fanspeed readings from a Thecus
|
||||
NAS device running SNMP.
|
||||
|
||||
=head1 APPLICABLE SYSTEMS
|
||||
|
||||
All Thecus NAS devices which have the third party NETSNMPD module installed.
|
||||
This is available at http://www.fajo.de/main/thecus/modules/netsnmpd
|
||||
|
||||
=head1 CONFIGURATION
|
||||
|
||||
As a rule SNMP plugins need site specific configuration. The default
|
||||
configuration (shown here) will only work on insecure sites/devices.
|
||||
|
||||
[snmp_*]
|
||||
env.version 2
|
||||
env.community public
|
||||
|
||||
In general SNMP is not very secure at all unless you use SNMP version
|
||||
3 which supports authentication and privacy (encryption). But in any
|
||||
case the community string for your devices should not be "public".
|
||||
|
||||
Please see 'perldoc Munin::Plugin::SNMP' for further configuration
|
||||
information.
|
||||
|
||||
=head1 INTERPRETATION
|
||||
|
||||
The plugin reports the current fan speed readings as reported by the thecusIO
|
||||
module.
|
||||
|
||||
=head1 MIB INFORMATION
|
||||
|
||||
Private MIB
|
||||
|
||||
=head1 MAGIC MARKERS
|
||||
|
||||
#%# family=snmpauto
|
||||
#%# capabilities=snmpconf
|
||||
|
||||
=head1 VERSION
|
||||
|
||||
0.0.20120307
|
||||
|
||||
=head1 BUGS
|
||||
|
||||
None known.
|
||||
|
||||
=head1 AUTHOR
|
||||
|
||||
Copyright (C) 2011 - 2012 Andreas Thienemann <andreas@bawue.net>
|
||||
|
||||
Based on the snmp__uptime plugin as a template.
|
||||
|
||||
=head1 LICENSE
|
||||
|
||||
GPLv2 or (at your option) any later version.
|
||||
|
||||
=cut
|
||||
|
||||
use strict;
|
||||
use Munin::Plugin::SNMP;
|
||||
use vars qw($DEBUG);
|
||||
|
||||
$DEBUG = $ENV{'MUNIN_DEBUG'};
|
||||
|
||||
my $response;
|
||||
|
||||
if (defined $ARGV[0] and $ARGV[0] eq "snmpconf") {
|
||||
print "index 1.3.6.1.4.1.14822.101.21.\n";
|
||||
print "require 1.3.6.1.4.1.14822.101.21.5200.1.1.0 [0-9]\n";
|
||||
print "require 1.3.6.1.4.1.14822.101.21.5200.1.2.0 [0-9]\n";
|
||||
exit 0;
|
||||
}
|
||||
|
||||
if (defined $ARGV[0] and $ARGV[0] eq "config") {
|
||||
my ($host) = Munin::Plugin::SNMP->config_session();
|
||||
print "host_name $host\n" unless $host eq 'localhost';
|
||||
print "graph_title Thecus Fans
|
||||
graph_args --base 1000 -l 0
|
||||
graph_vlabel RPM
|
||||
graph_info This graph shows the RPMs of the fans as reported by the ThecusIO module.
|
||||
graph_category sensors
|
||||
fan1.label Fan 1
|
||||
fan1.info Thecus CPU Fan
|
||||
fan2.label Fan 2
|
||||
fan2.info Thecus System Fan
|
||||
";
|
||||
exit 0;
|
||||
}
|
||||
|
||||
my $session = Munin::Plugin::SNMP->session(-translate =>
|
||||
[ -timeticks => 0x0 ]);
|
||||
|
||||
my $fan1 = $session->get_single ("1.3.6.1.4.1.14822.101.21.5200.1.1.0") || 'U';
|
||||
my $fan2 = $session->get_single ("1.3.6.1.4.1.14822.101.21.5200.1.2.0") || 'U';
|
||||
|
||||
#print "Retrived uptime is '$uptime'\n" if $DEBUG;
|
||||
|
||||
print "fan1.value ", $fan1, "\n";
|
||||
print "fan2.value ", $fan2, "\n";
|
Loading…