mirror of
https://github.com/munin-monitoring/contrib.git
synced 2018-11-08 00:59:34 +01:00
added graph info, added warning & critical alerts, data info, SMART errors and revised the scaling
This commit is contained in:
parent
eca3d0044a
commit
203f993d27
@ -4,15 +4,19 @@
|
||||
# This plugin can graph:- Currently Drive Temperature and Error Count
|
||||
#
|
||||
#---------------------
|
||||
#
|
||||
# Create a symbolic link to MegaRaid_{AdapterNumber}_{temp|error}
|
||||
# Examples
|
||||
# Create a symbolic link to MegaRaid_<AdapterNumber>_<temp|media|other|predictive>
|
||||
# ln -s /usr/share/munin/plugins/MegaRaid_ /etc/munin/plugins/MegaRaid_0_temp
|
||||
# graph temperature on adapter 0
|
||||
#
|
||||
# ln -s /usr/share/munin/plugins/MegaRaid_ /etc/munin/plugins/MegaRaid_0_error
|
||||
# graph media errors on adapter 0
|
||||
#
|
||||
# ln -s /usr/share/munin/plugins/MegaRaid_ /etc/munin/plugins/MegaRaid_1_temp
|
||||
# graph temperature on adapter 1
|
||||
#
|
||||
#---------------------
|
||||
#
|
||||
# $Log$
|
||||
# Log
|
||||
# Revision 0.1 2011/04/16 idobson
|
||||
# -First version only basic support of the MegaRaid controller
|
||||
#
|
||||
@ -26,6 +30,18 @@
|
||||
# Revision 1.1 2011/04/17 fkatzenb
|
||||
# -Revised scalling
|
||||
#
|
||||
# Revision 1.2 2011/04/28 fkatzenb
|
||||
# -Added support for graph_info support
|
||||
# -Added warning & critical alerts support
|
||||
# -Added data info
|
||||
#
|
||||
# Revision 2.0 2011/04/29 fkatzenb
|
||||
# -Added remaining support for SMART Errors
|
||||
#
|
||||
# Revision 2.1 2011/04/29 fkatzenb
|
||||
# -Added version information for in the graph description
|
||||
#
|
||||
#
|
||||
#---------------------
|
||||
#
|
||||
# Add the following to your /etc/munin/plugin-conf.d/munin-node:
|
||||
@ -41,6 +57,7 @@
|
||||
#%# family=auto
|
||||
#%# capabilities=autoconf
|
||||
#
|
||||
my $DisplayVer=2.1;
|
||||
|
||||
use strict;
|
||||
use warnings;
|
||||
@ -61,18 +78,48 @@ chomp $Command;
|
||||
my %config = (
|
||||
temp => {
|
||||
lookfor => 'Drive Temperature :',
|
||||
label => 'Drive Temp',
|
||||
label => 'Temp',
|
||||
title => "MegaRAID Adapter $Adapter: Drive Temperatures",
|
||||
vtitle => 'Celsius',
|
||||
graph_args => '--base 1000 -l 0'
|
||||
graph_args => '--base 1000 -l 0',
|
||||
warning => '55',
|
||||
critical => '65',
|
||||
info_tag => "Temperature (C)",
|
||||
description => "Internal Temperatures for drives on Adapter $Adapter."
|
||||
},
|
||||
error => {
|
||||
lookfor => 'Media Error Count: ',
|
||||
label => 'Drive Media Err',
|
||||
title => "MegaRAID Adapter $Adapter: Media Errors",
|
||||
label => 'Media Err',
|
||||
title => "MegaRAID Adapter $Adapter: Media Errors (SMART)",
|
||||
vtitle => 'Number of Errors',
|
||||
graph_args => '--base 1000 -l 0'
|
||||
graph_args => '--base 1000 -l 0',
|
||||
warning => '',
|
||||
critical => '',
|
||||
info_tag => "Media Errors (SMART)",
|
||||
description => "Number of SMART errors related to the drive's media on Adapter $Adapter."
|
||||
},
|
||||
other => {
|
||||
lookfor => 'Other Error Count: ',
|
||||
label => 'Other Err',
|
||||
title => "MegaRAID Adapter $Adapter: Others Errors (SMART)",
|
||||
vtitle => 'Number of Errors',
|
||||
graph_args => '--base 1000 -l 0',
|
||||
warning => '',
|
||||
critical => '',
|
||||
info_tag => "Other Errors (SMART)",
|
||||
description => "Number of SMART errors not related to the drive's media on Adapter $Adapter."
|
||||
},
|
||||
predictive => {
|
||||
lookfor => 'Predictive Failure Count: ',
|
||||
label => 'Predictive Err',
|
||||
title => "MegaRAID Adapter $Adapter: Predictive Errors (SMART)",
|
||||
vtitle => 'Number of Errors',
|
||||
graph_args => '--base 1000 -l 0',
|
||||
warning => '',
|
||||
critical => '',
|
||||
info_tag => "Predictive Errors (SMART)",
|
||||
description => "Number of SMART errors for each drive on Adapter $Adapter."
|
||||
}
|
||||
);
|
||||
|
||||
#Auto config options
|
||||
@ -97,6 +144,7 @@ if ($ARGV[0] and $ARGV[0] eq "config"){
|
||||
print "graph_args $config{$Type}->{graph_args}\n";
|
||||
print "graph_scale yes\n";
|
||||
print "graph_category disk\n";
|
||||
print "graph_info $config{$Type}->{description} <br />Generated by MegaRaid_, Version $DisplayVer<br />\n";
|
||||
|
||||
foreach my $Line (@Output) {
|
||||
$Line=~ s/\r//g;
|
||||
@ -106,7 +154,14 @@ if ($ARGV[0] and $ARGV[0] eq "config"){
|
||||
if ( $Line=~ m/Slot Number: /i ) {
|
||||
$DevID=$Line;
|
||||
$DevID=~ s/Slot Number: //;
|
||||
print "A".$Adapter."_D".$DevID."_$Type.label Adapter:$Adapter/Disk:$DevID $config{$Type}->{label}\n";
|
||||
print "A".$Adapter."_D".$DevID."_$Type.label A$Adapter:D$DevID $config{$Type}->{label}\n";
|
||||
print "A".$Adapter."_D".$DevID."_$Type.info Adapter: $Adapter / Drive: $DevID - $config{$Type}->{info_tag}\n";
|
||||
if ($config{$Type}->{warning} ne '' ) {
|
||||
print "A".$Adapter."_D".$DevID."_$Type.warning $config{$Type}->{warning}\n";
|
||||
}
|
||||
if ($config{$Type}->{critical} ne '') {
|
||||
print "A".$Adapter."_D".$DevID."_$Type.critical $config{$Type}->{critical}\n";
|
||||
}
|
||||
}
|
||||
}
|
||||
exit 0;
|
||||
|
Loading…
Reference in New Issue
Block a user